Test results reported for: Chilled Tech, LLC
Samples Covered in Report: ChilLED 1200W LED Light
CSA Report: CHIH004-050
Original issue date: 3/23/2017
Revision Issue Date: –
Prepared for:
Chilled Tech, LLC
service@chilledgrowlights.com
Test report prepared by:
Gabe Trippel
Project Engineer
Test & Measurement Services
Testing performed by:
CSA Group
14833 NE 87th St
Redmond, WA 98052
425-605-8500
www.csagroupseattle.org
Test report approved by:
Aaron Miller
Lab Manager
Test & Measurement Services
Lab sample identification:
Customer Identification:
Manufacturer:
Part number:
Model Number:
Description:
CHIH004-05
Chilled Tech, LLC
Chilled Tech, LLC
05
ChilLED 1200W LED Light
Large LED array grow light
Max Current (A):
Operating voltage:
Wattage (watts):
Frequency (Hz):
Dimmable:
–
–
–
–
–
Sample Device as Received
Sample Device Mounted to Test Apparatus
Photometric and electrical testing in accordance with IES LM 79-08 IES Approved Method for the Electrical and Photometric
Measurements of Solid-State Lighting Products. All measurements are made using the goniometer – spectroradiometer test method.

Test Conditions
Test Date: | March 17, 2017 |
Method: | goniometer-spectroradiometer |
x-axis Alignment: | 0.0 ± 0.001 m |
y-axis Alignment: | 0.0 ± 0.001 m |
z-axis Alignment: | 3 ± 0.001 m |
Theta Minimum: | 0 ± 0.10° |
Theta Maximum: | 90 ± 0.10° |
Theta Step Size: | 2.5 ± 0.10° |
Phi Minimum: | 0 ± 0.10° |
Phi Maximum: | 180 ± 0.10° |
Phi Step Size: | 22.5 ± 0.10° |
Ambient Temperature (°C): 25 ±1°C
Ambient Humidity (%RH): 24
Optical Measurements
Electrical Measurements
*Normailized, based on a single, on-axis measurement
*NOTE: Plot titles & units are incorrectly labelled “candela” (CD) and are actually in units of watts per steradian (W/sr).

†NOTE: Plots below are incorrectly labelled “footcandles/illuminance” and are actually in units of watts per sq ft (W/ft2).
Zonal Power Summary | ||
Zone | Watts | % Luminaire |
0-30 | 130.4 | 25.7% |
0-40 | 216.9 | 42.7% |
0-60 | 395.7 | 77.9% |
60-90 | 112.1 | 22.1% |
0-90 | 507.8 | 100.0% |
Watts Per Zone | ||
Zone | Watts | % Total |
0-10 | 15.6 | 3.1% |
10-20 | 45.1 | 8.9% |
20-30 | 69.7 | 13.7% |
30-40 | 86.4 | 17.0% |
40-50 | 92.7 | 18.2% |
50-60 | 86.1 | 17.0% |
60-70 | 66.2 | 13.0% |
70-80 | 37.3 | 7.3% |
80-90 | 8.7 | 1.7% |
Item | Description/use | Manufacturer | Model | Serial # |
Goniometer | Type-D | Orb Optronix | – | MS-STA-GON-07-001 |
Spectroradiometer | Optical Measurements | Orb Optronix | SP-200 | 2009063 |
Power Analyzer | Electrical Measurements | Yokogawa | WT310 | 760401 |