Photon Flux Test Report
Test results reported for: Horticultural integrating sphere testing
Samples Covered in Report: 1
Orb Optronix report: CHIH002-011
Original issue date: November 18, 2016
Revision Issue Date: November 21, 2016
Prepared for:
Chilled Tech, LLC
service@chilledgrowlights.com
Test report prepared by:
Marius Timbus
Technician
Test & Measurement Services
Testing performed by:
CSA Group
14833 NE 87th St
Redmond, WA 98052
425-605-8500
www.csagroupseattle.org
Test report approved by:
Aaron Miller
Lab Manager
Test & Measurement Services
Lab sample identification:
Customer Identification:
Manufacturer:
Part number:
Model Number:
Description:
01
1
Max Current (A):
Operating voltage:
Wattage (watts):
Frequency (Hz):
Dimmable:
0.7
60


2.1 REQUIREMENT:
Luminaire Efficacy, Photometric and Radiometric Data, PPF, YPF, CCT, CRI, Chromaticity Coordinates, Spectral Distribution, Tc, Vf, and If
Electrical Measurements
Photopic and Radiometric Measurements
PAR Measurements
Photosynthetic Photon Flux: weighted equally by wavelength and summed between 350nm and 750nm.
Yield Photon Flux: PPF weighted by action spectrum (average of 20 plant species as defined by McCree) and
summed between 350nm and 750nm. (See section 6.0)


REVISION | DATE | APPROVED | DESCRIPTION OF REVISION |
---|---|---|---|
010 | 11/18/2016 | ACM | ⓪ORIGINAL |
011 | 11/21/2016 | ACM | ①Added new graphs to Spectral Charts ②Included CCT and CRI to Results |
Item | Description/use | Manufacturer | Model | Serial # | Calibration Due |
Integrating Sphere | 60″ Diameter | Labsphere | AA-00462 | 10240111707 | at use |
Spectroradiometer | Instrument Systems | CAS-140 CT | 772514215 | at use | |