Test results reported for: Gravita
Samples Covered in Report: Gravita Pro 1000 DE (1000W setting)
CSA Report: CHIH004-011
Original issue date: 3/16/2017
Revision Issue Date: 4/3/2017
Prepared for:
Chilled Tech, LLC
service@chilledgrowlights.com
Test report prepared by:
Gabe Trippel
Project Engineer
Test & Measurement Services
Testing performed by:
CSA Group
14833 NE 87th St
Redmond, WA 98052
425-605-8500
www.csagroupseattle.org
Test report approved by:
Aaron Miller
Lab Manager
Test & Measurement Services
Lab sample identification:
Customer Identification:
Manufacturer:
Part number:
Model Number:
Description:
CHIH004-01
Chilled Tech, LLC
Gavita
–
Gavita Pro 1000 DE (1000W setting)
HPS Lamp and Ballast
Max Current (A):
Operating voltage:
Wattage (watts):
Frequency (Hz):
Dimmable:
5
240
1000
60
no
Sample Device as Received
Sample Device Mounted to Test Apparatus
Photometric and electrical testing in accordance with IES LM 79-08 IES Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. All measurements are made using the goniophotometer test method (See Section 6.0 for additional information).

Test Conditions
Test Date: | March 3, 2017 |
Method: | goniophotometer, spectroradiometer |
x-axis Alignment: | 0.0 ± 0.01 m |
y-axis Alignment: | 0.0 ± 0.01 m |
z-axis Alignment: | 0.0 ± 0.01 m |
Theta Minimum: | 0 ± 0.01° |
Theta Maximum: | 180 ± 0.01° |
Theta Step Size: | 2.5 ± 0.01° |
Phi Minimum: | 0 ± 0.01° |
Phi Maximum: | 180 ± 0.01° |
Phi Step Size: | 22.5 ± 0.01° |
Ambient Temperature (°C): 25 ±1°C
Ambient Humidity (%RH): 24
Optical Measurements
Electrical Measurements
*Normailized, based on a single, on-axis measurement
*NOTE: Plot titles & units are incorrectly labelled “candela” (CD) and are actually in units of watts per steradian (W/sr).

†NOTE: Plots below are incorrectly labelled “footcandles/illuminance” and are actually in units of watts per sq ft (W/ft2).
Zonal Power Summary | ||
Zone | Watts | % Luminaire |
0-30 | 66.0 | 17.3% |
0-40 | 119.1 | 31.1% |
0-60 | 261.3 | 68.4% |
60-90 | 119.5 | 31.3% |
70-100 | 37.8 | 9.9% |
90-120 | 0.7 | 0.2% |
0-90 | 380.8 | 99.6% |
90-180 | 1.4 | 0.4% |
0-180 | 382.2 | 100.0% |
Watts Per Zone | ||
Zone | Watts | % Total |
0-10 | 6.9 | 1.8% |
10-20 | 21.6 | 5.7% |
20-30 | 37.5 | 9.8% |
30-40 | 53.1 | 13.9% |
40-50 | 64.6 | 16.9% |
50-60 | 77.6 | 20.3% |
60-70 | 81.9 | 21.4% |
70-80 | 35.3 | 9.2% |
80-90 | 2.3 | 0.6% |
90-180 | 1.6 | 0.5% |
Item | Description/use | Manufacturer | Model | Serial # |
Goniometer | Type-C | Lighting Sciences | 6240T | N/A |
Optical Meter | Optical Measurements | Newport | 2936-R | METR010 |
Photodetector | Optical Measurements | INPHORA | IPR-PDET | 110902 |
Power Supply | Device Power Supply | Quadtech | 31015 | PSAC001 |
Power Analyzer | Electrical Measurements | Yokogawa | WT310 | C2QD10013V |